Search found 30 matches

by deech123
Thu Apr 16, 2020 3:53 pm
Forum: Using DIALux evo
Topic: strange behavior of calculation between same surfaces
Replies: 5
Views: 1263

Re: strange behavior of calculation between same surfaces

Hi,

you are right, that's the difference.

is there for way to set the automatic to pependicular instead of Adaptive?

seems that I can not change that, only if I draw a manual calculation surface.
by deech123
Wed Apr 15, 2020 6:33 pm
Forum: Using DIALux evo
Topic: strange behavior of calculation between same surfaces
Replies: 5
Views: 1263

strange behavior of calculation between same surfaces

Hi guys, I found something very strange in DAILux evo 9, do not know if it's due to the V9, but hope somebody can explain me this. if you look at my screenshot, you can see that the upper right calculation is the manual one, the 2nd one is the automatic one, you can see the difference very good. but...
by deech123
Thu Sep 26, 2019 3:01 pm
Forum: Problems
Topic: problems with report when using 2 floors and lightplan
Replies: 3
Views: 1768

Re: problems with report when using 2 floors and lightplan

HI ,

thx for the link, but I have the latest version of dialux, and with the article, there is not one clue how to achieve this.
in my report, there is still no plan of the lights hanging at the 2nd floor.

so any clue or tip guys to make my report correct again?

D.
by deech123
Thu Sep 19, 2019 8:20 am
Forum: Problems
Topic: problems with report when using 2 floors and lightplan
Replies: 3
Views: 1768

problems with report when using 2 floors and lightplan

Hi guys, I have a quit complex building where I encounter some problems with. Let me explain what I did so that it will be quit good to understand. first I created a ground floor level, then I duplicated this as 2nd floor and also as 3the floor. now some parts of that building are with cutouts in th...
by deech123
Tue Feb 05, 2019 7:50 am
Forum: Using DIALux evo
Topic: set required lux value on extra calculation objects inside a room
Replies: 4
Views: 2241

Re: set required lux value on extra calculation objects inside a room

no no, what I mean is, sometimes the end clients asks in a certain room for example 350 lux. and in the entire room (for example 4000m²) they want 350 lux and with a consistency of 0.4-0.6. so it can a bit higher and lower, but overal must fall inside the scoop of the client. hope I explain it a bit...
by deech123
Mon Feb 04, 2019 6:37 pm
Forum: Using DIALux evo
Topic: set required lux value on extra calculation objects inside a room
Replies: 4
Views: 2241

Re: set required lux value on extra calculation objects inside a room

seems, we are the only one that use this, but for me, 80% of the dialux study cases I make for clients are like that :-) hope we can have this option, or if it excist, we know where to find it. I'm also searching for a solution to make light calculation where you can set that the max lux value betwe...
by deech123
Fri Feb 01, 2019 1:19 pm
Forum: Using DIALux evo
Topic: set required lux value on extra calculation objects inside a room
Replies: 4
Views: 2241

set required lux value on extra calculation objects inside a room

Hi guys, a small question where I do not find any answer on the internet. if you have a big room like 100x100 meter you can set on that room that you required for example 300lux. but in some cases there are spots in that room where the client want 500lux. so what I do is making a new calculation sur...
by deech123
Fri Jan 11, 2019 7:40 am
Forum: Problems
Topic: difference in end result between IES file and IES converted to LDT by Dialux program
Replies: 4
Views: 2502

Re: difference in end result between IES file and IES converted to LDT by Dialux program

hi,

yes I also got your email.
and indeed there was a very small difference in the light width settings in LDT that caused the big UGR difference.

thx for the quick action !
this topic can be closed.

thx
Didier
by deech123
Wed Jan 09, 2019 3:52 pm
Forum: Problems
Topic: difference in end result between IES file and IES converted to LDT by Dialux program
Replies: 4
Views: 2502

Re: difference in end result between IES file and IES converted to LDT by Dialux program

HI,

just send an mail to support@dial.de, with the 2 dialux files,complete the same only the fixture is one time the IES an the other time the converted IES to LDT.
also you have the original IES file and the converted LDT also.

let me know what you found :-)

Didier
by deech123
Wed Jan 09, 2019 1:06 pm
Forum: Problems
Topic: difference in end result between IES file and IES converted to LDT by Dialux program
Replies: 4
Views: 2502

difference in end result between IES file and IES converted to LDT by Dialux program

Hi guys, after 1 day of investigation, and trying to test all possibilities we found a problem in de LDT editor of Dialux. I will try to explain it in simple words. we have our own .IES File we got back from light lab. we make a building in dialux, and place this IES file for example 7x6 fixtures. t...