by kvkozierowski
Thu Aug 01, 2019 5:51 am
Forum: Problems
Topic: Change in luminaire properties
Replies: 3
Views: 153

Re: Change in luminaire properties

Hi, CCT 3000K and CRI 100 is the default in DIALux when no spectral data are available. The IES data format is somehow limited so it might just be the default value used by evo. You can change the values in the lamp tool. CRI 100 is the typical CRI of incandescent/halogen lamps, it is not impossible...
by kvkozierowski
Fri Jul 19, 2019 12:26 pm
Forum: Problems
Topic: Problem with pdf output
Replies: 2
Views: 330

Re: Problem with pdf output

Hello, In most cases this happens if you have complex geometry in your project (furnitures, luminaire models etc.) and/or DWGs with many layers and lines. The reason is that these objects are rendered as SVGs for the 2D views (floor plan) in the output process. These SVGs can become so big that the ...
by kvkozierowski
Fri Jul 19, 2019 5:00 am
Forum: Problems
Topic: "Teilbereich ausschließen" schneidet in die Decke
Replies: 1
Views: 190

Re: "Teilbereich ausschließen" schneidet in die Decke

Hallo Herr Schonmann, wenn Sie die Funktion "Teilbereich ausschließen" und eine automatische abgehängte Decke ("Decke in Raum einfügen") verwenden, dann ist das Verhalten so gewollt. Mit der Funktion "Teilbereich ausschließen", sagen Sie dem Programm, dass dieser Teil nicht zu dem aktiven Bereich/Ra...
by kvkozierowski
Thu Jul 11, 2019 9:00 am
Forum: Wishes/suggestions
Topic: Light Scenes and Control Groups
Replies: 3
Views: 333

Re: Light Scenes and Control Groups

Yes, I know this is how it is implemented in DALI etc and the concept in Dx4. However you need to figure out which luminaires should be grouped together in one control group, this can be a complex task in big projects, especially if you need to change something later on. If EVO can implement that wh...
by kvkozierowski
Thu Jul 11, 2019 5:46 am
Forum: Wishes/suggestions
Topic: Light Scenes and Control Groups
Replies: 3
Views: 333

Re: Light Scenes and Control Groups

Hello DAB LAD, Thank you for your feedback concerning the light scenes and control/luminaire groups in evo. You are right, the current implementation in evo is not great at all, but there is a common misunderstanding (especially from people that know Dx4): luminaire groups and control groups are not...
by kvkozierowski
Fri Jun 14, 2019 11:48 am
Forum: Wishes/suggestions
Topic: MF standard
Replies: 5
Views: 621

Re: MF standard

To edit a profile you need to create a copy first, you cannot change the default profiles. standards.PNG You can change the selection but not the value of "Clean" etc. for the ambient condition. I am not sure if this will be implemented at all. For example for the daylight calculation there is an in...
by kvkozierowski
Thu Jun 13, 2019 8:13 am
Forum: Wishes/suggestions
Topic: MF standard
Replies: 5
Views: 621

Re: MF standard

Hello Henrik,

You can already create a copy of the european CIE97 template and create profiles according to your local standards in evo. You can find it under File->Settings...->Standards.

Best regards
Kolja
by kvkozierowski
Wed Jun 12, 2019 6:52 am
Forum: Construction
Topic: The poles (or masts) of lights not showing up in Building and Outdoor Planning
Replies: 1
Views: 319

Re: The poles (or masts) of lights not showing up in Building and Outdoor Planning

Hello Hannah,

The automatic pole placement is available in the street lighting only.
If you need a pole in a normal outdoor scene you can use a vertical cylinder or a 3ds model if you need special poles.

Best regards
Kolja
by kvkozierowski
Wed Jun 05, 2019 12:58 pm
Forum: Construction
Topic: Überdachte Aussenfläche
Replies: 1
Views: 304

Re: Überdachte Aussenfläche

Hallo, ich denke der Fall ist so nicht direkt vorgesehen, es gibt aber für die Konstruktion (mindestens) zwei Möglichkeiten: 1. Man konstruiert einen normalen Raum mit Dach usw. und schneidet anschließend mit dem Ausschnitttool die drei überflüssigen Wände weg. Damit erhält man dann ein Gebäude mit ...
by kvkozierowski
Tue May 28, 2019 5:15 am
Forum: Construction
Topic: Konstruktion Dach mit Oberlichter
Replies: 2
Views: 377

Re: Konstruktion Dach mit Oberlichter

Hallo Lena, wenn Sie eine Etage mit (Innen)Wänden vom Boden bis zum Dach haben möchten, können Sie ganz einfach die Etagenhöhe (im Etagentool) so anpassen, dass sie der Firsthöhe entspricht (4,73m). Beim Dach geben Sie als Position (Z) 2,73m an. Das Dach schneidet die Wände dann ab. dach2.PNG Gruß K...